Last updated: 3 November 2026
A JIC fitting seals metal to metal on a 37° cone; an ORFS fitting seals with an O-ring pressed against a flat face. That is the whole difference between JIC and ORFS hydraulic fittings, and it decides everything else: how each one is identified, how it is tightened, where it leaks and why the two never connect directly, even when the threads match. If you are holding an unmarked fitting off a loader, a press or a power unit, this guide shows how to tell which one you have, how to read the size and how to join the two when a machine uses both.
The short version
JIC and ORFS fittings differ in how they seal, and every other difference in this table follows from that. Any one row is enough to identify the fitting in your hand.
| Point of comparison | JIC 37° flare | ORFS (O-ring face seal) |
|---|---|---|
| Standard | SAE J514, ISO 8434-2 | SAE J1453, ISO 8434-3 |
| Male end | Cone-shaped nose at 37° | Flat face with an O-ring sitting in a groove |
| How it seals | Metal to metal, cone against the flared tube or swivel seat | The O-ring is squeezed against the flat face of the mating part |
| Seal parts | None. The metal surfaces are the seal | One O-ring, which is a wear part and can be replaced |
| Main leak cause | Over- or under-tightening, or a damaged cone or flare | A cut, missing, wrong or hardened O-ring |
| Where it is common | Industrial and mobile hydraulics, test points, older equipment | Mobile and off-highway machines, high pressure and high vibration lines |
| Parker name and code letter | Triple-Lok. Part codes carry an X, for example 6 FTX-S | Seal-Lok. Part codes carry an L, for example 6 FLO-S |
A JIC fitting seals where its 37° cone meets a matching 37° seat, with no gasket or O-ring between them. On a tube joint the seat is the flared end of the tube, held in place by a nut and sleeve. On a hose fitting the seat is inside the female swivel nut. Parker's Triple-Lok catalog puts it simply: sealing in Triple-Lok fittings takes place between two smooth metal surfaces.
Because nothing in the joint is soft, a JIC fitting has no elastomer to age or limit its temperature, and the same fitting can usually be taken apart and remade. The cost is that the seal depends entirely on the metal and the tightening. Too little torque leaves a leak path; too much flattens or cracks the cone or flare, and that joint will weep from then on. Follow the assembly torque in the fitting maker's catalog. Parker also makes a Triple-Lok Soft Seal version with an O-ring in the nose, which adds an elastomer seal to the metal-to-metal joint.
An ORFS fitting seals with an O-ring held in a groove on its flat male face, squeezed against the flat face of the female swivel or sleeve. The threads only pull the faces together. Because the O-ring does the sealing, an ORFS joint is less sensitive to exact tightening than a metal-to-metal joint, which is why ORFS is the usual choice on machines that see high pressure, pressure spikes and constant vibration.
The O-ring is also the weak point. A pinched, cut or missing O-ring is the first thing to check when an ORFS joint leaks, and a replacement has to be the right size, material and hardness for the fluid and temperature. Keep the O-ring and the flat face clean during assembly, and do not reuse an O-ring that has taken a set.
The quickest way to tell JIC from ORFS is to look at the end of the male fitting: a cone is JIC, a flat face with an O-ring is ORFS. If the fitting is still on the machine or you need to be certain, work through all four checks.
For both JIC and ORFS tube fittings, the dash size is the tube outside diameter in sixteenths of an inch, but the threads are different for the same dash size. So a -6 fitting is for 3/8 in. tube in either system. A -6 JIC has a 9/16-18 thread and a -6 ORFS has an 11/16-16 thread.
| Dash size | Tube OD | JIC 37° thread (SAE J514) | ORFS thread (SAE J1453) |
|---|---|---|---|
| -4 | 1/4 in. | 7/16-20 | 9/16-18 |
| -6 | 3/8 in. | 9/16-18 | 11/16-16 |
| -8 | 1/2 in. | 3/4-16 | 13/16-16 |
| -10 | 5/8 in. | 7/8-14 | 1-14 |
| -12 | 3/4 in. | 1-1/16-12 | 1-3/16-12 |
| -16 | 1 in. | 1-5/16-12 | 1-7/16-12 |
| -20 | 1-1/4 in. | 1-5/8-12 | 1-11/16-12 |
| -24 | 1-1/2 in. | 1-7/8-12 | 2-12 |
The 9/16-18 trap: a -6 JIC male and a -4 ORFS female share the same 9/16-18 thread. The nut will run down and feel tight, but a 37° cone cannot seal against a flat O-ring face. The joint will leak under pressure, and it can let go. Never mix the two. Use a conversion adapter.
Thread data comes from SAE J514 and SAE J1453 as published in manufacturers' thread identification guides. Check the fitting maker's catalog for sizes not shown here.
Yes, but only through a conversion adapter that has a JIC end on one side and an ORFS end on the other. This is common when a replacement hose comes with a different end from the port or tube it has to join, or when ORFS components are fitted to an older JIC machine. We stock Parker conversion fittings in both directions:
Match the dash size on each end to the line you are joining, and confirm the thread on both sides before you order. If the two lines are different sizes, send us both measurements and we will find the right adapter.
ORFS is the better choice where leaks are expensive and the line sees high pressure or vibration; JIC is the better choice where parts must be easy to find, reuse and remake. Neither is better everywhere. In practice the machine decides, because you replace like with like unless you are re-plumbing a whole circuit.
Parker sells JIC 37° fittings as Triple-Lok and ORFS fittings as Seal-Lok, and we stock both in steel. The examples below are -6 (3/8 in. tube) parts. Use them to read the code, then browse the full range.
| What you need | Triple-Lok (JIC 37°) | Seal-Lok (ORFS) |
|---|---|---|
| Straight adapter to NPT pipe thread | 6 FTX-S | 6 FLO-S |
| Union, tube to tube | 6 HTX-S | 6 HLO-S |
| Nut or swivel | 6 BTX-S tube nut | 6 C6LO-S swivel elbow |
| Full range | JIC flared fittings | O-ring face seal fittings |
For crimped hose ends, Parker hose fittings use the same JIC and ORFS ends. Our Parker page explains how to read a hose fitting part number, and the Parker Triple-Lok catalog (PDF) has full dimensions.
Livingston & Haven splits this work across two sites: fittings and ordering are on the store, and hydraulic engineering, repair and training are here. Livingston & Haven was founded in 1947 and is based in Charlotte, North Carolina.
| What you need | Where to go |
|---|---|
| JIC 37° fittings | JIC flared fittings, on the store |
| ORFS fittings | O-ring face seal fittings, on the store |
| Many part numbers at once | Quick Order |
| Help with a mobile machine | Mobile hydraulics |
| Help with the circuit, not just the fitting | Industrial hydraulics engineering |
| Another hydraulic comparison | Pressure relief valve vs pressure reducing valve |
A JIC fitting seals metal to metal where a 37° cone meets a 37° seat. An ORFS fitting seals with an O-ring held in a groove on a flat face. JIC follows SAE J514 and ORFS follows SAE J1453, and their threads differ for the same dash size.
No. They seal in different ways and use different threads for the same dash size. Some sizes share a thread, such as 9/16-18 on a -6 JIC and a -4 ORFS, but they will not seal together. Join them with a JIC to ORFS conversion adapter.
A standard JIC fitting does not. It seals metal to metal on the 37° cone. Parker also makes a Triple-Lok Soft Seal version with an O-ring in the nose, which adds an elastomer seal to the 37° joint.
Yes. A -6 JIC fitting is sized for 3/8 in. outside diameter tube. Its thread is 9/16-18, not 3/8, so measure the thread rather than looking for a 3/8 in. dimension on the fitting.
It depends on the dash size. Common sizes are -4 9/16-18, -6 11/16-16, -8 13/16-16, -10 1-14, -12 1-3/16-12 and -16 1-7/16-12, as set by SAE J1453.
No. NPT is a tapered pipe thread that seals on the threads, usually with sealant. JIC has a straight thread that only holds the joint together, and it seals on the 37° cone. Adapters such as the Parker 6 FTX-S join a JIC line to an NPT port.
Send a photo of the fitting end and the thread measurement, or the part number off the old fitting, and our team will identify it and quote the Parker part that matches.
Or call 1-800-825-4969